Mechanical diaphragm metering pump

Mechanical diaphragm metering pump

α- Dose series mechanical diaphragm metering pump

Mainly used in various water treatment processes such as municipal tap water, municipal sewage, industrial wastewater, and circulating water, as well as the addition of various chemicals.


Typical dosing medium

Acid-base, flocculants, polymer, hypochlorous acid disinfectants, dyes and additives, catalysts, and others.

Product performance parameters

▶  Flow range: 2~5500L/h

▶  Maximum discharge pressure: 10bar

▶  Adjustment ratio 10:1, steady-state accuracy ± 2%

▶  Inhalation lifting height: up to 3 meters of water column

▶  Maximum inlet pressure: 2 bar

▶  Maximum temperature allowed for materials: 45 ℃

▶  Maximum allowable material viscosity: up to 1200cP


Main features of the hydraulic end

▶  Hydraulic end material: PVC; PVDF; 316SS

▶  Diaphragm material: high-grade PTFE

▶  Valve ball material: glass; Ceramics; 316SS

▶  Specially designed valve seat ensures that the pump is running or stopped, and the valve seat has no leakage

▶  Multiple professional application pump head configurations: high viscosity, slurry, concentrated sulfuric acid, sodium hypochlorite, etc

▶  Self cleaning one-way valve structure


Main features of the driver end

▶ Variable eccentric mechanism adjusts stroke length to ensure smooth flow pulsation changes

▶ Enhanced structural design, suitable for pulsating impacts and harsh operating environments

▶ Sliding bearings and high-strength worm gear and worm gear ensure long-term stable operation


Flow regulation method

Manual adjustment: adjust the stroke length with the handwheel

▶ Flow regulation can be achieved regardless of whether the pump is running or stopped

▶ The minimum adjustment scale is 1%

Electric stroke controller: receives external control signals and adjusts stroke length

▶ Power supply: 220V-50Hz - single-phase

▶ Input signal: 4-20mA analog signal

▶ Output signal: 4-20mA/1-5V analog signal, for recording, display, and control system use

Variable frequency controller: receives external control signals and adjusts stroke length

▶ Power supply: 220V-50Hz single-phase/380V-50Hz three-phase

▶ Input signal: 4-20mA analog signal